Industrial Consultancy & Sponsored Research (IC&SR) , IIT Madras
Crest Ultrasonics Corporation
Chemistry & Chemical Engineering
Experiments were conducted on various material substrates at various input parameter levels, and particle removal efficiencies were quantified using laser particle counters.
Particle removal efficiency of ultrasonic and megasonic systems as a function of various input parameters ()frequency, power level, etc.) has never been systematically studied.
Correlation was established between particle removal efficiency and ultrasonic/ megasonic field parameters for various substrates and particle sizes.